The JL-301A series of bulb holder controls is designed for automatically managing garden, corridor, and entrance lighting based on the surrounding natural light conditions. It is advisable to use the JL-301A exclusively with tungsten bulbs.
JL-301A E26 Bulb Socket Specifications
Model No.
JL-301A
Rated Voltage
120VAC
Rated Frequency
60Hz
Rated Loading
150W Tungsten
Power Consumption
0.5W Max.
Typical On/Off Level
20~40 Lx
Ambient Temperature
-40℃ ~ +70℃
Related Humidity
96%
Failure Mode
Fail-Off
Adapter
E26
Certifications
JL-301A E26 Bulb Socket Installation
Disconnect power.
Screw bulb off.
Screw the unit into bulb holder completely.
Screw bulb into the bulb holder of the unit.
Connect power. Turn lamp switch ON.
Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Avoid to use the unit in an opaque or reflective glass lantern, as well as use in a wet place.